Electrostatic Oil Cleaner
|
|
|
Manufactured in Bangalore by us we are presenting EOC or electrostatic oil cleaner. It is an electrostatic super oil cleaning equipment that involves static charging of ionised suspended solid contaminants in fluids like oils and collecting them on an enormously spread surface of di-electric media. The entire cleaning process is conducted off-line, meaning that the parent machine need not be shut down. |
 |
 |  "save oil" "save energy" by electrostatic liquid cleaning (elc) machine and help environment during oil cleaning by elc machine save electricity energy by adopting new version of elc 25 & elc 50 machine specification for selection guide | oil iso vg / elc model | 32 | 46 | 68 | 100 | 150 | electric power | dimension (lxwxh mm) | weight in kg. Approx | | elc -25l regular | 6000 l | 4200 l | 2800 l | 1500 l | 600 l | 225 w | 635x450x875 | 120 | | elc -25l new version | 12000 l | 8300 l | 5600 l | 3000 l | 1500 l | 250 w | 635x450x875 | 125 | | elc -50l regular | 12000 l | 8300 l | 5600 l | 3000 l | 1500 l | 425 w | 775x450x850 | 150 | | elc -50l new version | 12000 l | 8300 l | 5600 l | 3000 l | 1500 l | 250 w | 775x450x850 | 145 | | elc-100l regular | 30000 l | 20000 l | 17000 l | 7600 l | 3500 l | 450 w | 915x600x875 | 210 | cost comparison of new version model | model of elc machine | electric motor h. P. | pump lpm | load hvt kvdc | running cost of electric motor 300 days/1 year | saving on electric motor cost per 1 year | cost of dust collector per 1 year | saving on cost of dust collector cost per 1 year | cleaning capacity if compare with regular model | cost of oil cleaning per 1 ltr. On saving of electric motor load & hvt capacity | | elc-25l regular | 0. 25 | 3 | 6 | rs 6000 | nil | rs. 4000 | nil | regular | rs. 2. 50 | | elc-25l new version | 0. 25 | 3 | 12 | rs 6000 | nil | rs. 6000 | nil | double | rs. 1. 50 | | elc-50l regular | 0. 5 | 12 | 12 | rs 12000 | nil | rs. 8000 | nil | regular | rs. 3. 00 | | elc-50l new version | 0. 25 | 5 | 12 | rs 6000 | rs 6000 | rs. 6000 | rs. 2000 | regular | rs. 2. 00 | | elc-100l regular | 0. 5 | 12 | 12+12 | rs 12000 | nil | rs. 16000 | nil | regular | rs. 1. 50 | |
 | - Keeps the oil clean at all times (contamination level NAS6, Moisture 300ppm) Enhances total acid number and viscosity enormously Does not affect oil contents such as additives during precise flushing operation Completely removes free moisture, dissolved moisture and gas by applying high vacuum method (70Torr.abs or under)
- Eliminates contaminant particles down to the level of sub-microns equal to or smaller than 1/ffli using electrical absorption technology Eliminates sub-micron corpuscles which are the cause for viscosity change to prevent the oxidation of oil and extend life Possible to flush up to highly viscous oil (maximum 460cst) Completely eliminates moisture in oil by double vacuum chamber method Automatic discharge of condensed moisture through the automatic moisture discharger
- In case the oil leaks, issues automatic warning and stops the equipment using leakage prevention apparatus
- OFF-LINE method which does not affect the operation of main facilities Unattended operation by using automatic control program Maintains the oil function to the optimum state to enhance productivity of the equipment
- Precisely eliminates oxidation products to prevent accident of the equipment and reduces maintenance cost
- Flushes the hydraulic line based on continuous operation
- Prevents temperature rise and fixation of bearing due to friction Minimizes the equipment damages due to friction
| Division | | SYVE10 | SYVE20 | SYVE30 | SYVE40 | | External Dimension (mm) | Width | 1200 | 1250 | 1450 | 1650 | | | Length | 1350 | 1400 | 1450 | 1450 | | | Height | 1900 | 1920 | 2020 | 2060 | | Weight (MAX) | | 590 kg | 760 kg | 900 kg | 1100 kg | |
 |  - Exclusively designed for synthetic and phosphoric ester polymer oil such as EHC HPU oil
- Reduces total acid number noticeably and maintains it at a low level
- Eliminates contaminant particles down to the level of sub-microns using electrical absorption and filter technology
- Faster and more precise elimination of contaminated particles compared with SYVE Models
- Keeps the oil clean at all times to the contamination level at or lower than NAS5
- Maintains moisture saturation under 300ppm
- Enhances viscosity of the operating oil and maintains it at a constant level
- Does not affect oil contents such as additives during precise flushing operation
- Completely removes free moisture, dissolved moisture and gas by applying high vacuum method (70Torr.abs or under)
- Eliminates sub-micron corpuscles which are the cause for viscosity change to prevent the oxidation of oil and extend life
- Completely eliminates moisture in oil by double vacuum chamber method Automatic discharge of condensed moisture through the automatic moisture discharger
- In case the oil leaks, issues automatic warning and stops the equipment using leakage prevention apparatus OFF-LINE method which does not affect the operation of main facilities
- Unattended operation by using automatic control program
- Used VITON materials for various pipes, hoses, and seals
| Division | | Equipment Model No. | | | | | External Dimension (mm) | Width | 1200 | 1250 | 1450 | 1650 | | | Length | 1350 | 1450 | 1650 | 1650 | | | Height | 1900 | 1920 | 2020 | 2060 | |
 |  APPLICATIONS - Plastics Injection Moulding Machines.
- Hot Press in plywood Industries.
- Aluminum Extrusion & Die Casting Machines.
- Power Generation Plant & Hydro Power Plant.
- CNC Machine Tools.
- Ceramics Industries,
- Aviation, Railways & Automobiles.
- Hydraulic Press & Hot / Cold Steel Mills.
- Bearing Lubrication System.
- Earth Moving, Construction & Mining Equipments.
- Power Transmission Plant.
ADVANTAGES - Eliminate Oil Changes.
- Eliminate Mechanical Filters.
- Increase Production And Reduce Rejection.
- Increase Life of pumps, Valves & Seals.
- EH&S (Environment, Health & Safety) friendly.
- Longer Oil life.
- No Oil Leakages
- Longer Equipment Life.
- Low Operation and Maintenance Cost.
- Energy Saving by keeping Oil Clean.
SPECIFICATION FOR SELECTION GUIDE | Oil ISO VG / ELC Model | 32 | 46 | 68 | 100 | 150 | Electric Power | Dimension (LxWxH mm) | Pump Flow Ltr/Min | Weight in kg. Approx | | ELC -25L | 6000 L | 4200 L | 2800 L | 1500 L | 600 L | 225 L | 635x450x850 | 5 at 50Hz | 120 | | ELC -50L | 12000 L | 8300 L | 5600 L | 3000 L | 1500 L | 425 L | 835x450x850 | 12 at 50Hz | 150 | | ELC -100L | 30000 L | 20000 L | 17000 L | 7600 L | 3500 L | 475 L | 915x600x875 | 12 at 50Hz | 210 | The ELC system uses the principles of electrostatics to collect fuild contaminants. ELC unique design with gradient force permits it to take advantage of the natural charge that each contaminant contains. Contamination that have a positive charge are drawn towards a negative electrode plate within the system while those with an inherent negative charge are drawn towards a positive plate. Neutral contaminants are drawn and deposited by gradient force to the edge of the collectors where the intensity of the deformed electric field is strongest. As the fluid flows freely through the system. ELC removes contaminants, submicronic particles as 0.01 micron, dust, dirt and products of oxidation such as tars and varnishes. ELC also removes particles such as paper, wood, plastic and rubber. Contaminants are trapped on Cellulose Collectors for easy disposal. ELC will not affect soluble additives. The Dust collector paper(s) is hosted in the oil cleaning chamber. Each Dust Collector is made of disposable cellulose fiber and in form of pleated to hold the greatest quantity of contaminants. Dust collector can hold as much as 4.5 kgs. Before change is required and will furnish 2000 hours of use depending upon the actual contaminants of oil. |
|
|